Skip to content
IntellobotsTechnologies

Set up · How-to

Industrial I/O modules

Connect PLC and I/O modules directly or behind a gateway, and use their readings in rules.

Updated 11 Nov 20261 min read

All ThingsX IoT Core pages

Industrial I/O (IIO) modules behave like other devices:

  • Directly connected modules (with their own network connection) are like Wi-Fi devices: they get a certificate or password, publish telemetry and receive commands. See Connect Wi-Fi and IoT devices.
  • Modules behind a gateway (for example on a fieldbus the gateway reads) are child devices with the gateway as their parent, like shelf labels. See BLE gateways and child devices.

Good practice

  • Send counters as running totals (door_cycles: 1281) rather than increments, so a lost message doesn't skew your numbers.
  • Put the site and asset in attributes (site: DC-PUNE, dock: 3) so the Things list and rules can filter on them.
  • Use events for alarms ({"type": "motor_overcurrent"}) and rules to route them to your maintenance system.